Our Network, Services and Infrastructure

Ingenuity operates multi-homed network infrastructure which provides extra reliability as well as better network performance for your website and email due to its diverse backbone network connectivity.

Our Tier-1 backbone service providers have been specially chosen to ensure optimal routing to all local, Asia-Pacific and International internet destinations is achieved. These providers are:

COMindico / Sptel Ethernet - 1 Gigabit / sec
Connect.com / AAPT Ethernet - 1 Gigabit / sec
Optus Ethernet - 1 Gigabit / sec
Optus (2nd link) ATM STM1 – 155 / Megabit / sec
Powertel Ethernet – 1 Gigabit / sec
UECOMM Ethernet - 100 megabit / sec
Pipe Peering Ethernet – 1 Gigabit / sec

The Data Centre housing Ingenuity's equipment is located in the Brisbane CBD, Queensland Australia. This data centre has been constructed to the highest possible environmental standards and in accordance with industry best practice. It has the best supply of electricity in Brisbane and has less then 1 minor power outage every 2 years.

Power:
The Data Centre is supplied by 3 Phase 410Amp per phase building rising main. The building has three separate independent 1Megawatt generators located on the 17th and 18th floors of the building, capable of supplying more then enough power for the entire building. The generators are directly connected into the essential services supply and are capable of switching over in the instant there is a power failure. In the event of a power outage, the UPS will carry the load until the building generators are automatically started and start supplying power.

Environmental System:
The Data Centre has 2 separate independent 90Kilowatt Leibert under floor Air Conditioners. Each Air unit is capable of supplying the room by itself. The Data Centre has over 100 Pairs of Multimode fibre running up and down the building. The fibre run is designed to link to every Telco in Brisbane. The Data Centre is fitted with a Fire suppression system more than capable of controlling any situations that may arise. This is monitored by the building security, the Ingenuity staff and the local authorities. The system is not easily fooled, and will only activate once the temperature is 90 Degrees Celsius.

Security:
The Data Centre has multiple security cameras fitted inside and outside of the centre that records all movement with in the confined area.

Redundancy:
Redundant servers are located in Melbourne and interlinked network conections exist in Brisbane, Sydney, Melbourne and Perth to ensure the continual flow of data. Weekly off-site web server backups are performed for emergency data retrieval if all other systems fail.